Page 219 - PHU_User Manual_EN_Rev A
P. 219

APPENDIX

                            Rated load  ms  30   30   30     30     30
                     *8
               Rise time
                            No load   ms  30   30     30     30     30
                            Rated load  ms  80   80   80     80     80
                    *9
               Fall time
                            No load   ms  1000   1000   1000   1200   1000
               Transient response     ms  1.5   1.5   1.5    1.5    1.5
               time *10

               Model                PHU 1500-10  80-340   200-140  500-60   750-40
               Line regulation *3      mV  150   8    20     50     75
               [0.01% of Vo_rated]
               Load regulation *4      mV  300   16   40     100    150
               [0.02% of Vo_rated]
                              *6
                            p-p     mV  2400   200    300    350    800
                          *5
               Ripple and noise    *7
                            r.m.s.    mV  400   16    40     70     200
               Temperature          ppm 100ppm/°C of rated output voltage, after a 30 minute
               coefficient          / °C  warm-up.
               Remote sense
               compensation         V   75     4      10     25     37.5
               voltage
                            Rated load  ms  30   30   30     30     30
                     *8
               Rise time
                            No load   ms  30   30     30     30     30
                            Rated load  ms  80   80   80     80     80
                    *9
               Fall time
                            No load   ms  1200   1000   1000   1000   1200
               Transient response     ms  1.5   1.5   1.5    1.5    1.5
               time *10

               Model                PHU 1000-30  1500-20  80-510   200-210  500-90
               Line regulation *3
               [0.01% of Vo_rated]   mV  100   150    8      20     50
               Load regulation *4      mV  200   300   16    40     100
               [0.02% of Vo_rated]
                              *6
                            p-p     mV  1600   2400   200    300    350
               Ripple and noise
                          *5
                                *7
                            r.m.s.    mV  350   400   16     40     70
               Temperature          ppm 100ppm/°C of rated output voltage, after a 30 minute
               coefficient          / °C  warm-up.
               Remote sense
               compensation         V   50     75     4      10     25
               voltage
                            Rated load  ms  30   30   30     30     30
                     *8
               Rise time
                            No load   ms  30   30     30     30     30
                            Rated load  ms  80   80   80     80     80
                    *9
               Fall time
                            No load   ms  1000   1200   1000   1000   1000
               Transient response
               time *10             ms  1.5    1.5    1.5    1.5    1.5





                                                                         219
   214   215   216   217   218   219   220   221   222   223   224